Welding Generator Inspection
An inspection sheet for engine-driven welder generators, covering engine, output, fuel and safety.
Why keep this record
Engine driven welders provide power in the field where no outlet exists. They also run engines, fuel and electrical output in the same unit, so inspection covers three fields: engine, welder and safety. A machine that has been sitting may have stale fuel, a dead battery or a clogged filter. Check the unit before each trip and give it a thorough inspection each season. Run it outdoors or with exhaust piped outside, since engine exhaust contains carbon monoxide.
Worksheet
| Inspection point | Result | Action |
|---|---|---|
| Engine oil level and condition | ||
| Fuel quality and leaks | ||
| Air filter | ||
| Battery and cables | ||
| Coolant or cooling fins | ||
| Exhaust and spark arrestor | ||
| Output leads and receptacles | ||
| Ground and frame bond | ||
| Controls and gauges | ||
| Guards, covers and fire extinguisher |
How to complete it
- Check oil and coolant levels on a level surface before starting.
- Look for fuel leaks, old fuel and water in the sediment bowl or filter.
- Inspect the air filter and clean or replace it if it is dirty.
- Check the battery terminals for corrosion and that the cables are tight.
- Start the engine and listen for unusual noise, then check the output with a meter if available.
- Inspect leads, plugs and receptacles for damage, and make sure the machine is grounded as required.
A sample entry
Engine oil changed after 100 hours. Fuel was three months old, drained and replaced with fresh and stabilizer. Air filter cleaned. Battery terminals cleaned and tightened. Output leads checked, one plug worn and replaced. Started and loaded for ten minutes with no problems.
Reading the results
If the engine hunts or loses power under load, check fuel, filters and the governor. If output is weak, check connections and brushes. Keep a log of hours and service, since maintenance on schedule prevents most field failures.
Shop tip
Add fuel stabilizer at the end of each season and run the engine dry or fill the tank full before storage. Cover the machine, and store it dry. Keep spare filters, oil and a spark plug with the unit. A generator is only useful when it starts on the day you need it.
Common mistakes
- Running the engine in a closed shop, where exhaust builds up.
- Leaving old fuel in the tank over winter.
- Ignoring a worn power cord until it sparks.
Stop and get help if
- You smell fuel or see a leak.
- The engine runs rough or overheats.
- The unit has no guard on moving parts.
Keeping the record
Fuel only when the engine is off and cool, and keep a fire extinguisher near the machine. Run the engine outdoors with plenty of air, and keep it away from open flames and hay.