Welding & Fabrication

Torch Flashback Arrestor Check

A check sheet for flashback arrestors and check valves on oxy-fuel and fuel gas systems.

Why keep this record

A flashback is a flame that burns backward through the hose toward the cylinder. It can rupture hoses, damage regulators and start fires. Flashback arrestors stop the flame, and check valves stop reverse gas flow. They are small, cheap safety devices that are often missing, old or installed wrong. This sheet records where each is fitted, when it was tested and what condition it is in, so that you do not discover a missing arrestor after an accident.

Worksheet

ItemLocation (torch or regulator)GasTest dateCondition and action
Oxygen arrestor at regulator
Fuel gas arrestor at regulator
Oxygen arrestor at torch
Fuel gas arrestor at torch
Oxygen check valve
Fuel gas check valve
Hose connections
Regulator gauges
Cylinder valves
Replacement due date

How to complete it

  1. Identify each arrestor and check valve by its labels, and write which gas and location each belongs to.
  2. Test each device according to the manufacturer's instructions, including any flow and reverse flow tests.
  3. Look for corrosion, damage, loose fittings and missing labels.
  4. Confirm that the arrestor is correct for the gas and pressure and installed in the right direction.
  5. Replace any unit that fails a test or has been through a flashback.
  6. Record the date and set the next test date.

A sample entry

Both regulators have arrestors, installed 2021, tested last month and passed. The torch end has check valves, one with a damaged thread that was replaced. Oxygen hose clamps tightened. All fittings dry, gauge zeroes confirmed. Next test due in six months.

Reading the results

Treat any flashback as a failure of the system. Close the valves, move away, inspect for fire and replace hoses and arrestors before using again. Review how the flashback occurred, such as an incorrect pressure or a blocked tip.

Shop tip

Light the torch correctly and shut down in the proper sequence, as your supplier teaches, since most flashbacks come from procedure errors. Blow out the line before lighting, use the right tip size and keep the tip clean. A written start and stop routine posted by the torch helps everyone follow the same steps.

Common mistakes

  • Installing an arrestor backward.
  • Assuming a new arrestor never needs testing.
  • Reusing equipment that has been through a flashback without inspection.

Stop and get help if

  • A flashback has happened and the equipment has not been inspected.
  • An arrestor will not pass a test or is damaged.
  • You are not certain which direction the device should face.

Keeping the record

Follow the manufacturer's instructions for testing, since methods differ. Many suppliers will test or replace arrestors for a small fee, and some local rules require them.