Cutting Table Safety Audit
An audit sheet for plasma, torch and abrasive cutting tables, covering fire, fumes, grounding and housekeeping.
Why keep this record
Cutting tables concentrate sparks, hot slag, fumes and electrical current into a small area, and they are often placed against a wall where everything else ends up stored. An audit once a month, with a record of fixes, keeps the table safe. The audit also protects you if an insurer asks how hot work is controlled. Do it with the table cold and the power disconnected, and bring a flashlight to see under the grate.
Worksheet
| Audit item | Pass / Fail | Fix needed | Date fixed |
|---|---|---|---|
| Slats or grate in good condition | |||
| Slag tray emptied | |||
| No combustibles within 35 feet | |||
| Floor swept and free of oil | |||
| Ground clamp contact clean | |||
| Fume extraction or open airflow | |||
| Fire extinguisher charged and near | |||
| Eye and face protection available | |||
| Hearing protection available | |||
| Cylinders and hoses clear of sparks |
How to complete it
- Disconnect power and let the table cool before the audit begins.
- Check each item on the list and mark pass or fail honestly.
- Measure the distance to cardboard, rags, paint and fuel, and move anything within the zone.
- Empty slag trays into a metal container, never a plastic bin.
- Test that the work clamp makes bright metal contact and the cable is not cracked.
- Write a fix and a date for every fail, then recheck.
A sample entry
Slats worn thin along the front edge, replaced. Slag tray full of fine dust and two bolts, emptied into a steel pail. A cardboard box of rags was against the wall behind the table, moved outside. Ground clamp cleaned with a wire brush. Fire extinguisher inspected and tagged.
Reading the results
Fire risk usually sits beside the table, not on it. Look at where sparks travel for the whole cutting height and room corner, and give extra attention to anything that smolders after you leave. A common rule is to watch the area for at least thirty minutes after hot work ends.
Shop tip
Mount a small fire extinguisher at the table's edge, on the exit side, so you can reach it without crossing the hot zone. Paint a red outline on the floor around the table as a no-storage area. A visible boundary prevents the slow creep of boxes, hoses and cans toward the sparks.
Common mistakes
- Storing paint or rags behind the table.
- Letting slag pile up under the grate.
- Skipping the audit after the table has been moved.
Stop and get help if
- Slag has built up under the table and smells of burning.
- Fumes linger in the room after cutting.
- You find damaged leads or exposed conductors.
Keeping the record
A cutting table is also a magnet for clutter. A painted line on the floor around it, kept clear, is the cheapest safety control in the shop.